P/N: 6001-3001


200 Amp TH Series Time Delay Relay (TDR) 

  • Whole vehicle auxiliary load manager automatically protects batteries from inadvertent discharge

  • 200 Amps continuous / 260 Amps intermittent / 12 Vdc

  • Adjustable Open delay from 15 min to 16 hrs, 5 second test mode

  • Ultra-Low 1.5 mA OFF current draw, 5-10 times lower than competitors

  • Withstands harsh environments (fully sealed, stainless steel hardware)

  • Open time delay can be triggered via ignition key signal or input terminal voltage sense. Voltage sense may optionally be disabled

  • Optional low voltage and high voltage shut-off protection 

  • Optional Kill Switch input forces relay open until signal is removed

  • Internal thermal overload protection

  • 4 year product replacement warranty on all new TH Series products

P/N: 7616

 

Dual Output TH Series Time Delay Relay (TDR) 

  • Provides two high-amp disconnects with separate programmable time delay settings

  • 2x80 Amps continuous / 2x120 Amps intermittent / 12 Vdc

  • Additional low-amp (500 mA) output turns off 30 sec before output #1 for initiating orderly shut-down of critical components sensitive to sudden power loss

  • Adjustable Open delay from 0 sec to 4 hrs, 5 second test mode

  • Ultra-Low 1.5 mA OFF current draw, 10-20 times lower than alternate solutions

  • Withstands harsh environments (fully sealed, stainless steel hardware)

  • Open time delay triggered via ignition key / other signal or input voltage. Input voltage sense trigger response may optionally be disabled

  • Optional low voltage and high voltage shut-off protection  

  • Custom configurations available (terminal sizes, voltage/time/input responses)

P/N: 7601


160 Amp TH Series Time Delay Relay (TDR) 

  • Whole vehicle auxiliary load manager automatically protects batteries from inadvertent discharge

  • 160 Amps continuous / 220 Amps intermittent / 12 Vdc

  • Adjustable Open delay from 15 min to 16 hrs, 5 second test mode

  • Ultra-Low 1.5 mA OFF current draw, 5-10 times lower than competitors

  • Withstands harsh environments (fully sealed, stainless steel hardware)

  • Open time delay can be triggered via ignition key signal or input terminal voltage sense. Voltage sense may optionally be disabled

  • Optional low voltage and high voltage shut-off protection 

  • Optional Kill Switch input forces relay open until signal is removed

  • Internal thermal overload protection

  • 4 year product replacement warranty on all new TH Series products

P/N: 5601


30 Amp PT Series Time Delay Relay   

  • Protects batteries from being drained by incremental loads

  • Isolates sensitive incremental electronic loads from starting system voltage spikes

  • 30 Amps continuous / 40 Amps intermittent / 12 Vdc

  • Adjustable Open delay from 15 min to 8 hrs, 5 second test mode

  • Open time delay can be triggered via ignition key signal or input wire voltage sense. Voltage sense may optionally be disabled

  • Ultra-Low 1.5 mA OFF current draw, 5-10 times lower than competitors

  • Withstands harsh environ ments  (fully sealed)

  • Optional low voltage and high voltage shut-off protection

  • Internal thermal overload protection

  • 4 year product replacement warranty on all new TH Series products

P/N: 7614


Dual Battery Charge Manager - 80 Amp Electrical Load Relay (with Optional Time Delay) PLUS 80 Amp Charge Management Relay   

  • Replaces Multiple Devices - Significantly reduces cost, space used & off-state current draw

  • Per Channel: 80 Amps continuous / 120 Amps intermittent / 12 Vdc  

  • Adjustable Open delay from 0 sec to 4 hrs, 5 second test mode

  • Ultra-Low 1.5 mA OFF current draw, 10-20 times less that competitive solutions

  • Withstands harsh environments (fully sealed relay, potted electronics)

  • Open time delay can be triggered via ignition key signal or input terminal voltage sense. Voltage sense may optionally be disabled

  • Optional low voltage and high voltage shut-off protection

  • Optional Kill Switch input forces relay open until signal is removed

  • Internal thermal overload protection

Legacy Products

P/N: 6001


Top H.A.T. Battery Saver - High Amp Battery Saver   

  • 200 Amps continuous / 200 Amps intermittent / 12 Vdc

  • Adjustable Open delay from 15 min to 16 hrs, 5 second test mode

  • Low 6 mA OFF current draw

  • Withstands harsh environments (fully sealed relay, potted electronics)

  • Open time delay can be triggered via ignition key signal or input terminal voltage sense. Voltage sense may optionally be disabled

  • Optional low voltage and high voltage shut-off protection

P/N: 5201


Power Tamer VS - 25 Amp Battery Saver R 4.0 - Legacy Drop-In Design 

  • Revision 4.0 design, drop in replacement to all legacy revisions

  • 25 Amps max intermittent / 20 Amps continuous / 12 Vdc

  • Adjustable Open delay from 15 min to 16 hrs, 5 second test mode

  • Low 7 mA OFF current draw, 50% less than competitors

  • Withstands harsh environments (fully potted), LED Indicators

  • Open time delay can be triggered via ignition key signal (optional) or input terminal voltage sense (standard)

  • Low voltage and high voltage shut-off protection

P/N: 5201-2001


Power Tamer VS - 25 Amp Battery Saver - New Smaller Footprint

  • 25 Amps max intermittent / 20 Amps continuous / 12 Vdc

  • Adjustable Open delay from 15 min to 16 hrs, 5 second test mode

  • Low 7 mA OFF current draw, 50% less than competitors

  • Withstands harsh environments (fully potted), LED Indicators

  • Open time delay can be triggered via ignition key signal (optional) or input terminal voltage sense (standard)

  • Low voltage and high voltage shut-off protection

P/N: 5001


Power Tamer - Low Amp Battery Saver   

  • 30 Amps max intermittent / 25 Amps continuous / 12 Vdc

  • Adjustable Open delay from 15 min to 31 hrs, 4 second test mode

  • Low 5 mA OFF current dra w,  50% less than competitors

  • Withstands harsh environments (fully potted)

  • Open time delay can be triggered via ignition key signal (optional) or input terminal voltage sense (standard)

  • Low voltage and high voltage shut-off protection

P/N: 4101


Dock Master - Laptop Power Manager with Shutdown Coordination

  • 20 Amps continuous / 25 Amps intermittent / 12 Vdc

  • Utilizes Windows software to manage time delay and triggering.

  • 5 minute laptop warning of shut down, optional override.

  • Open time delay can be triggered via ignition key signal (optional) or input terminal voltage sense (standard)

  • Low voltage shut-off protection

P/N: 6301


Top H.A.T. Solid State - High Amp Battery Saver   

  • 120 Amps continuous / 160 Amps intermittent / 12 Vdc

  • Programmable Open delay from 6 sec to 4.5 days 

  • Programmable voltage thresholds for under/over and low voltage

  • Solid state, draws very low current in ON state compared to relays

  • Withstands harsh environments (fully potted)

  • Open time delay can be triggered via ignition key signal or input terminal voltage sense. Voltage sense may optionally be disabled

  • Optional low voltage and high voltage shut-off protection

P/N: 8001


Power Master 6 - High-Amp Multi-Output Battery Saver   

  • 6 independent outputs / 180 Amps total / 30 Amps per output / 12 Vdc

  • Programmable Open delay from 6 sec to 4.5 days for each output

  • Solid state, draws very low current in ON state compared to relays

  • Withstands harsh environments (fully potted)

  • Open time delay can be triggered via ignition key signal or input terminal voltage sense. Voltage sense may optionally be disabled

  • Optional low voltage and high voltage shut-off protection