TH3 - Dual Time Delay Relay, Bulk Pack

    160.70 160.70000000000002 USD 160.70

    160.70

    This combination does not exist.


     Find Distributors                      Local Sales Reps


    For Direct OEM/Distributor Pricing, Contact Us At: sales@egismobile.com 
    Shipping: 2-3 Business Days


    TOP SIDE DIP SWITCHES

    Accessible after installation, for programming time delay and determining active features. Protected by self-retained cover.


    STAINLESS STEEL SELF-LOCKING HARDWARE

    100% Non-ferrous corrosion resistant materials. All attachment screws and nuts are self-locking.


    INTEGRAL I/O CONNECTOR

    Rapid and 100% correct assembly via Molex MX-150 connector eliminates poor field connections.


    STANDARD AND OPTIONAL HARNESSES

    Mating plug with 2 feet of ground and ignition wire included. Optional harnesses with additional outputs and alternate wire lengths available


    EASY INTEGRATION WITH CT FUSE BLOCKS

    Optional EasyLink bus bars provide reduces space and cost to connect TDRs with CT series Fuse Blocks.


    EASY INTEGRATION WITH RT FUSE BLOCKS

    Optional EasyLink bus bars provide reduces space and cost to connect TDRs with RT series Fuse Blocks.


    LED DIAGNOSTICS

    Provides indication of pending relay OFF event due to under/over voltage or external off trigger. Output on/off status also provided. 

     

     

    PRIMARY SPECIFICATIONS


    Maximum current -

    Continuous:   80 Amps DC per Output (160 A Total)

    Intermittent:   120 Amps DC (5 Minutes) per Output

    Off State Current Draw

    1.5 mA (less than 1 Amp-hr battery dissipation per month of stand-by)

    Operating Specifications

    Voltage:           12 Vdc Nominal (8 - 18 Vdc)

    Temperature:  -40 to 85 Deg C

    Product Warranty

    4 Years from date of manufacturer

     


    Time Delay Options

    5 Sec through 4 hours via Dip Switches

    Environment Protection Standards 

    Waterproof to IP66 . IP6K9K

    Ignition Protected to ISO 8846

    Optional Features

    Input stud voltage sense trigger for relay OFF

    Under-voltage and over-voltage load protection

    Application Example 

    Entire Vehicle Switching and Circuit Protection

    Combining a high-amp TH Series Time Delay Relay (TDR) with a 5015 Fuse Block attached to the TDR input stud (left) provides 24 hour / keep-alive circuits; while the second 5015 Fuse Block (right) attaches to the output stud of the TDR providing switched circuits for the installation. The TDR can operate both as a remotely controlled switch and optionally in an autonomous mode after a prescribed time from a trigger event or due to a low input voltage situation. Fuse blocks shown without included covers.

    Odoo • Text and Image
                     

    Installation Example 

    12 Position RT Fuse Block, RT Ground Block, and TH Series Time Delay Relay (TDR)

    A well installed power distribution and clean ground return solution. Fused vehicle power is connected to the TDR Time Delay Relay (upper right), then distributed to the 12 Position RT Fuse Block (left). The RT Ground Block (lower right) was separate from the Fuse Block where it was originally tied together, and re-located to a more convenient locations for effective wire harness routing. Also shown, optional cover labels from emergency vehicle label sheet set.

    Odoo • Text and Image
                     

    DOWNLOADS

    7616 Dual Time Delay Relay
    Sales Sheet & Installation Guide

    3D STEP CAD Model




    140 A Time Delay Relay (TDR), Top Hat Replacement, Bulk Pack