P/N: 5015



10 Position Fuse Block with Low Amp Output Connectors

  • 8 ATO/ATC/ATU fused outputs, 1-25 Amps (fuses sold separately)

  • 2 LP J-Case fuse outputs, 30-60 Amps (fuses sold separately)

  • Snap-fit cover w/ label recesses (optional weatherproof label sets)

  • Molex MX-150 output connector allows plug and play builds

  • Standard and custom output harness assemblies sold separately

  • 160 Amps max per block, 20 Amps maximum per ATO/ATC circuit

P/N: 8025




6 Position Fuse & Ground Block with LED Indication

  • 6 ATO/ATC/ATU fused outputs (fuses sold separately)

  • 12 position ground return block, separable or integrated

  • 2 spare fuse locations / Clear cover with label recesses

  • LED blown fuse indication provides rapid system fault diagnosis

  • 100 Amp maximum, 30 Amp maximum per circuit

P/N: 8026




12 Position Fuse & Ground Block with LED Indication

  • 12 ATO/ATC/ATU fused outputs (fuses sold separately)

  • 12 position ground return block, separable or integrated

  • 4 spare fuse locations / Clear cover with label recesses

  • LED blown fuse indication provides rapid system fault diagnosis

  • 100 Amp maximum, 30 Amp max per circuit

P/N: 8028




6 Position Fuse Block with LED Indication

  • 6 ATO/ATC/ATU fused outputs (fuses sold separately)

  • 2 spare fuse locations / Clear cover with label recesses

  • LED blown fuse indication provides rapid system fault diagnosis

  • 100 Amp maximum, 30 Amp maximum per circuit

P/N: 8029




12 Position Fuse Block with LED Indication

  • 12 ATO/ATC/ATU fused outputs (fuses sold separately)

  • 4 spare fuse locations / Clear cover with label recesses

  • LED blown fuse indication provides rapid system fault diagnosis

  • 100 Amp maximum, 30 Amp maximum per circuit

P/N: 8032




18 Position Fuse Block with LED Indication

  • 18 ATO/ATC/ATU fused outputs (fuses sold separately)

  • 6 spare fuse locations / Clear cover with label recesses

  • LED blown fuse indication provides rapid system fault diagnosis

  • 100 Amp maximum, 30 Amp maximum per circuit

P/N: 8031




18 Position Fuse & Ground Block with LED Indication

  • 18 ATO/ATC/ATU fused outputs (fuses sold separately)

  • 12 position ground return block, separable or integrated

  • 6 spare fuse locations / Clear cover with label recesses

  • LED blown fuse indication provides rapid system fault diagnosis

  • 100 Amp maximum, 30 Amp maximum per circuit

P/N: 8030




12 Position Distribution / Ground Block 

  • 12 position Screw Terminal block, can be used alone or in conjunction with fuse terminal blocks and a ground return block or a positive distribution block if proper circuit protection and wire gauges are utilized 

  • 100 Amp maximum, 30 Amp maximum per circuit